Construction Specialties

Wall protection | Expansion joint covers | Entrance matting

+44 (0)1296 652800
Menu
  • Home
  • Products
    • Acrovyn® Wall & Door Protection
      Acrovyn® Doors & Door Protection
      Acrovyn by Design® Bespoke Wall Coverings
      Explovent® Safety Venting
      Explovent® Explosion Venting
      Omniwall Prefabricated Serviced Wall Systems
      Elimax Reform Flat Packed Serviced Wall Systems
      Allway® Expansion Joint Covers
      Entrance Flooring
      Pedisystems® Entrance Flooring
      Architectural Louvres
      Architectural Louvres
      Exterior Solar Shading
      Architectural Grilles
      Online Shop
      Conspec Contracts Installation Service
  • Projects
  • Blog
  • Resources
    • Brochures
      Best Practice Guides
      Market Sectors
      NBS Source Specifications
      CPD Seminars
      BIM Objects
      Acrovyn tutorials - FR
      Installation Service
      Legislation & Compliance
      On-Demand Webinars
      Virtual Product Samples
  • About Us
  • Contact
    • Nos Distributeurs
      Le fabricant
  • Careers

How to Calculate Louvre Pressure Drop – FR pictures

Louvre pressure drop is one of the key parameters of establishing the louvre requirements for your project as it’s based on the needs of the building and its ventilation system, rather than “free area” which doesn’t really mean anything.

Pressure drop is defined as the pressure differential from one side of a louvre to the opposite side, often expressed in Pascals (Pa). Louvre pressure drop occurs when frictional forces, caused by the resistance to flow, act on air moving through a louvre.

Increased louvre pressure drop can prevent equipment inside the ventilated area drawing sufficient air through the louvre, resulting in overheating, as the equipment has to work harder to draw the air through.

For a real life example, think about what happens when you partially block the intake of a hairdryer. The increased pressure drop requires the motor to work harder to draw air through, reducing the amount of air getting through and the element overheats.

Scale this up to a real situation and consider air being drawn into a heating and ventilating system. The results could be catastrophic!

The Louvre Pressure Drop Calculation

There’s a formula you can use (pictured below), just plug in the numbers in the right places and you (should) have the right answer. This pressure drop number must be passed to your mechanical engineer for them to determine whether this number is acceptable. If it isn’t you may need to consider increasing, or decreasing, the amount of louvre on your building.

Air Density (ρ)
is generally 1.225 kg/m³ (at sea level)

Volumetric Flow (qv)
is supplied by the ventilation engineer and relates to the amount of air required through the system

Core Area (A) & Discharge Loss Coefficient (CD)
are provided by your chosen louvre manufacturer

Example Louvre Pressure Drop Calculation

For this example we are working from an example structural opening of 2m² and have decided to specify the CS RSH-5700 Performance Louvre which has a coefficient of 0.32. The Core area, the area of the louvre without mullions, jamb and head, would be 1.796m². Our mechanical engineer has told us that he requires a Volumetric Flow of 3.78m³ for his air conditioning unit to operate efficiently, and we have assumed an air density of 1.225 kg/m³.

Opening

Overall opening = 2m²

Chosen Louvre

CS RSH-5700 with a Coefficient of 0.32

Core Area

Core Area = 1.796m²

Volumetric Flow

volumetric flow

Volumetric Flow = 3.78m³

Calculatrice de perte de charge d’une grille de ventilation

Recevoir le résultat par email

Guide

  • La densité ρ = 1,225 kg/m3. Elle correspond à la densité de l’air sec au niveau de la mer à la température de 15°C.
  • Débit volumique de ventilation en m3/s (qv). Cette donnée est fournie par l’ingénieur en charge de la ventilation et correspond au volume d’air ventilé requis pour le projet.
  • Surface nette d’aération exprimé en m² (A). Cette donnée est propre à chaque grille de ventilation et est fournie dans ses spécifications.
  • Coefficient de performance aéraulique (Cd). Cette donnée est aussi propre à chaque grille de ventilation et est fournie dans ses spécifications.

Or alternatively, using your trusty calculator, you can follow the instructions below to work everything out manually.

Starting Formula

Δp : Pressure Drop (Pa)
ρ : Air Density (kg/m3)  *
Q :  Volumetric Flow (m3/s)
Ac : Louvre Core Area (m2)
Ci/d : Louvre Coefficient
*   Assume ρ to be 1.225kg/m3

So there you have it, that’s how you calculate Louvre pressure drop, if you get stuck, confused or need any help please let us know, we’re happy to help. We’ve got a lot of experience in louvre specification so feel free to get in touch via:

  • phone: +44 (0)1296 652800
  • email: sales@c-sgroup.co.uk
newsletter_visuel

Vous avez apprécié cet article ?

Tous les deux mois, nous compilons nos meilleurs contenus dans notre lettre d'actualité

Filed Under: Blog

Louvres

What's in the brochure
  • - Industry Leading Products
  • - Innovative New Design Options
  • - Detailed Technical Information
  • - Louvre Specification Guidance

+44 (0)1296 652800
sales@c-sgroup.co.uk
Order a Sample
Request an Estimate
Get Technical Help

Menu

  • CS Products
  • Projects
  • Blog
  • About us
  • Contact Us
  • Pick Country

Contact

Construction Specialties UK Ltd
1010 Westcott Venture Park
Westcott, Bucks, HP18 0XB
United Kingdom
Get Directions
Tel: +44 (0)1296 652800
Fax: +44 (0)1296 652888
Email: sales@c-sgroup.co.uk

Privacy

This website uses cookies to help us give you the best experience when you visit our website. By continuing to use this website, you consent to our use of these cookies. Find out more about how we use cookies and how to manage them below in our privacy policy.
Privacy Policy

Copyright © 2025 · Construction Specialties

Copyright © 2025 · Genesis Framework · WordPress · Log in