The RFP Series is a simple to install, gasketed parking joint cover featuring aluminium cover plates over the rubber wings.
Economical, and highly effective, the RFP allows structural movement within busy car parks, without the risk of joint cover damage.
Available in 2 models for 30mm and 50mm joints.
Model | Joint Width | Overall Profile Width (mm) | Exposed Surface (mm) | Min Recess Required (mm) | Horizontal | Vertical |
---|---|---|---|---|---|---|
RFP-30 | 30 | 193 | 193 | 0 | 10 | 20 |
RFPW-30 | 30 | 110 | 110 | 0 | 10 | 20 |
Model | Joint Width | Overall Profile Width (mm) | Exposed Surface (mm) | Min Recess Required (mm) | Horizontal | Vertical |
---|---|---|---|---|---|---|
RFP-50 | 50 | 215 | 215 | 0 | 10 | 20 |
RFPW-50 | 50 | 133 | 133 | 0 | 10 | 20 |
Movement Details
FLOOR TO FLOOR COVERS:
To order any of the below models, please call +44 (0)1296 652800
Model | Rapid Ship? | Joint Width (mm) | Frame Thickness (mm) | Exposed Surface (mm) | Horizontal Movement (mm) | Vertical Movement (mm) | Lateral Movement (mm) |
---|---|---|---|---|---|---|---|
RFP-100 | NO | 30 | 9 | 193 | ±10 | ±20 | ±5 |
RFP-200 | NO | 50 | 9 | 215 | ±15 | ±20 | ±10 |
FLOOR TO WALL COVERS:
To order any of the below models, please call +44 (0)1296 652800
Model | Rapid Ship? | Joint Width (mm) | Frame Thickness (mm) | Exposed Surface (mm) | Horizontal Movement (mm) | Vertical Movement (mm) | Lateral Movement (mm) |
---|---|---|---|---|---|---|---|
RFPW-100 | NO | 30 | 9 | 111 | ±10 | ±20 | ±5 |
RFPW-200 | NO | 50 | 9 | 133 | ±15 | ±20 | ±10 |
Materials, Colours & Finishes
- Aluminium sections: mill finished as standard
- Gaskets: EPDM rubber, Black as standard
Fixings
The cover is installed using adhesive (supplied by CS) to adhere the gasket to the substrate, and mechanical fixings (by others) securing the aluminium profiles to the floor:
- Floor: fixings (by others) to suit substrate at 330mm centres and to achieve minimum 40mm embedment
- Wall: fixings (by others) to suit substrate at 330mm centres.
Note: frames are supplied pre-drilled
The standard adhesive used with RFP models is not compatible with bituminous finishes, such as asphalt. Please contact us for alternative solutions.
To ensure successful installation of the system the substrate temperature at the time of installation should be 5°C or above.